Hotline

0919243248
AIR-SAVER G2 Compressed air energy saver
AIR-SAVER G2 Compressed air energy saver

AIR-SAVER G2 Compressed air energy saver

Product code:

Model: AIR-SAVER G2

Contact

AIR-SAVER G2
Compressed air energy saver
A typical compressed air system has air losses through pipe works connections and leaking float type drains etc. By installing an AIR-SAVER the end user will limit air losses. At the end of the working day the AIR-SAVER will close off the air flow and save the generated compressed air in the air receiver.

The AIR-SAVER is typically installed on the air outlet of the air receiver. Alternatively, it is applied in larger factories to close off certain parts of the compressed air system, where during certain parts of the day no compressed air is required.

The AIR-SAVER has proven its worth and saved millions m3 of compressed air around the world. The AIR-SAVER helps end-users save valuable compressed air from escaping unnecessarily, reducing compressor running hours and thus extending its lifetime, saving energy and operating costs.

A simple – yet exciting programming module!

The control module offers programming simplicity and exciting display features, offering you visual information and company branding options.

AIR-SAVER G2
Compressed air energy saver
A typical compressed air system has air losses through pipe works connections and leaking float type drains etc. By installing an AIR-SAVER the end user will limit air losses. At the end of the working day the AIR-SAVER will close off the air flow and save the generated compressed air in the air receiver.

The AIR-SAVER is typically installed on the air outlet of the air receiver. Alternatively, it is applied in larger factories to close off certain parts of the compressed air system, where during certain parts of the day no compressed air is required.

The AIR-SAVER has proven its worth and saved millions m3 of compressed air around the world. The AIR-SAVER helps end-users save valuable compressed air from escaping unnecessarily, reducing compressor running hours and thus extending its lifetime, saving energy and operating costs.

A simple – yet exciting programming module!

The control module offers programming simplicity and exciting display features, offering you visual information and company branding options.

MIN./MAX. SYSTEM PRESSURE
0 - 16 bar

MIN./MAX. MEDIUM TEMPERATURE
1 - 100 °C

MIN./MAX. AMBIENT TEMPERATURE
1 - 50 °C

SUPPLY VOLTAGE OPTIONS
115 VAC or 230 VAC 50/60 Hz.

POWER CONSUMPTION
Approx. 9 W during cycle rotation

ENCLOSURE PROTECTION RATING
IP54 (NEMA13)

VALVE INLET/OUTLET CONNECTIONS
2" (BSP or NPT)

VALVE OPENING/CLOSING DURATION
105 sec. (90°)

VALVE HOUSING MATERIAL
Brass valve, nickel plated

ILLUMINATED LCD DISPLAY
Indicating day, time, valve status, battery life

BATTERY TYPE
CR2032, 3 volt

PROGRAMMABLE OPTIONS
Week planner, max. 100 switching points, to be distributed over 1-7 days

MANUAL OVERRIDE
Yes

REMOTE CONTROLLABLE
Yes (optional)

The FLEX function allows you to adjust and set the valve’s opening and closing times, a very useful feature in overtime situations or shutdowns.

 

 

 

The programming module displays important information such as the actual valve position and it also shows you when the AIR-SAVER weekly program is overruled, either manually or remotely switched. When remotely switched, the weekly program is overruled. In this case the display will change color (red) and additionally shows you a warning symbol and the text "REMOTELY SWITCHED".

 

 

 

Multiple display colors offering you the possibility to select a display color that best matches your company’s house style (or even that of your customer)!

 

 

 

  • Typically installed on the air outlet of the air receiver or alternatively applied to close off certain parts of the compressed air system
  • A potential daily saving of at least one air receiver’s worth of compressed air
  • Compressor, dryer and filter activities are reduced during factory closing hours
  • No unnecessary compressor start-ups during periods when compressed air is not required
  • Reduced maintenance requirements and lower power consumption leads to considerable savings on service and energy costs
  • Time programmed or remote controlled
  • A 3 volt CR2032 (long lifespan) battery saves the entered switching program and actual day and time settings in case of a power cut or failure
  • A red flashing display will inform you for an upcoming battery change
  • The REMOTE SWITCHING KIT allows you to control the AIR-SAVER remotely which is useful when the AIR-SAVER is installed high off the ground
  • Manual valve opening and closing possible, in case of a power failure
  • Slow valve opening to avoid "water hammer" in pipe line system
  • Brass valve, nickel plated
  • Compact design - Easy to install

Related products

LOCATOR

LOCATOR

Price: Contact
LOCATOR-EV

LOCATOR-EV

Price: Contact

COPYRIGHT © 2023 | Design Web: Phuong Nam Vina